Why put an ECU in your vehicle that was never designed to operate in the environment you will be using it in? Our ECU’s are designed from the ground up to withstand the harsh real world environment of Off-Road Racing and Marine use that no other aftermarket system can meet or match! Meeting automotive industry standard ‘under hood’ environmental requirements for 12 volt and 24 volt systems, marine industry environmental requirements, with the vibration and heat cycle specs to water tight and sealed, with an operating depth of up to 10′ under water. Our ECU’s can do it ALL!

The Pro128 processor at 56mhz- 9v to 32v

ENVIRONMENTAL RATINGS: Validation tests included extreme operating temperatures (-40° to +105° C), thermal shock, humidity, salt spray, salt fog, immersion, fluid resistance, mechanical shock, vibration, and EMC. It is the responsibility of the application engineer to assure that the application does not exceed the demonstrated capabilities of the unit; vibration or thermal.

  • STORAGE TEMPERATURE: -40° to +125° C
  • OPERATING TEMPERATURE: -40° to +105° C
  • THERMAL SHOCK: -40° to +125° C transition within 10s for 500 cycles
  • FLUID RESISTANCE: Two stroke motor oil, Four stroke motor oil, Unleaded gasoline, ASTM Reference ‘C’ fuel
  • HUMIDITY RESISTANCE: 85% humidity at 85°C for 1000 hours of operation
  • SALT FOG RESISTANCE: 1000 hours
  • IMMERSION: Submersible in 8% saltwater solution to 10′
  • MECAHANICAL SHOCK: 50 hours of 50 g’s
  • DROP: Random drop tests on concrete from 6′ 6.11 VIBRATION: Engine mountable and tested to high-performance levels
  • ABNORMAL SUPPLY VOLTAGE RESISTANCE: Conditions Supply Voltage Time Reverse Battery -24VDC 5 Minutes Abnormal Alternator Output 36VDC 5 Minutes Minimum Battery 6VDC Indef.

The Pro112 processor at 80mhz- 9v to 16v

 ENVIRONMENTAL RATINGS: The Pro112 is designed for automotive, under hood and marine industry environmental requirements. Validation tests include extreme operating temperatures, thermal shock, humidity, salt spray, salt fog, immersion, fluid resistance, mechanical shock, vibration, and EMC.

  • Storage Temperature –40 °C to +125 °C
  • Operating Temperature –40 °C to +105 °C
  • Thermal Shock –40 °C to +125 °C
  • Fluid Resistance Two-stroke motor oil, four-stroke motor oil, unleaded gasoline, ASTM Reference ‘C’ fuel
  • Humidity Resistance 90 % humidity at 85 °C for 1000 hours
  • Salt Fog Resistance 500 hours. 5 % salt fog, 35 °C
  • Immersion 4.34 psi test (simulated 3 m / 10 feet), salt water, 20 minutes Mechanical Shock 50 G’s, 11 ms, half-sine wave
  • Drop Test Drop test on concrete from 1 m Vibration

This ECM family has been successfully deployed in engine mounted applications ranging from common small displacement engines to large racing engines with extreme vibrations.

 

The Pro70w processor at 80mhz- 8v to 32v

ENVIRONMENTAL RATINGS:
  • Operating Voltage 8–32 Vdc
  • Operating Temperature –40 to +105 °C / –40 to +221 °F
  • Storage Temperature –40 to +105 °C / –40 to +221 °F
  • Mechanical Vibration RV3 (22.1 Grms)
  • Mechanical Shock 50 g, 11 ms, half-sine wave, 4 shocks in each direction (24 total shocks)
  • EMI/RFI Specification – SAE J1113-41 (Radiated and Conducted Emissions), SAE J1113-13 (ESD), SAE J1113-21 (Radiated RF Immunity), SAE J1113-11 (Transient Testing)  
 

The Pro48 processor at 56mhz- 9v to 16v

 ENVIRONMENTAL RATINGS: The ECM is designed to meet automotive industry standard under hood environmental requirements for 12 volt systems, and also meets marine industry environmental requirements. Validation tests included extreme operating temperatures (-40 to 105C), thermal shock, humidity, salt spray, salt fog, immersion, fluid resistance, mechanical shock, vibration, and EMC.
  • STORAGE TEMPERATURE: -40° to +125° C
  • OPERATING TEMPERATURE: -40° to +105° C
  • THERMAL SHOCK: -40° to +125° C, air-air, 500 cyc, 6 min. each point.
  • FLUID RESISTANCE: Lubricating oil, Unleaded gasoline, Long life coolant Hydraulic fluid, Transmission fluid
  • HUMIDITY RESISTANCE: 85% humidity at 85°C for 1000 hours of operation
  • SALT FOG RESISTANCE: 500 hours, 5%, 35° C
  • IMMERSION: Submersible in 8% saltwater solution to 10′
  • MECHANICAL SHOCK: 40 g peak, 3 planes, saw tooth
  • DROP: 1 meter, 6 surfaces on concrete 5.11 VIBRATION: Engine mountable and tested high-perf level
WARNING: It is against the law to install this part on an Emissions Controlled Vehicle. This part is legal for sale and use on Uncontrolled (Non-Emissions Controlled) Vehicles and Racing Use Only Vehicles. It is the responsibility of the installer and/or user of this product to ensure compliance with all applicable local and federal laws and regulations. Please check with your local vehicle authority before purchasing, using or installing any Professional EFI Systems Inc. product.
IMPORTANT EMISSIONS NOTICE:
In many states, it is unlawful to tamper with your vehicle’s emissions equipment. Professional EFI Systems Inc. products are designed and sold for sanctioned off-road/competition non-emissions controlled vehicles only and may never be used on a public road or highway. Using Professional EFI Systems Inc. products for street/road use on public roads or highways is prohibited by law unless a specific regulatory exemption exists. (more information can be found on www.semasan.com/emissions for state by state details in the USA)